永发信息网

能给我发个VB与三菱PLC通讯的源代码实例吗,非常感谢啊

答案:3  悬赏:70  手机版
解决时间 2021-04-03 10:59
能给我发个VB与三菱PLC通讯的源代码实例吗,非常感谢啊
最佳答案
得说明是什么型号的PLC啊,串口还是网口,VB6还是VB.NET?
算了,写段代码,VB.NET与Q系列以太网通讯的:
Imports System.Net
Imports System.Runtime.InteropServices
Public Class Form1

    Dim Handle1 As Int32
    Dim EntLink1 As Boolean
    Dim ScanCount1 As Long
    Dim PLC As New EntQsPlc_Asc.PlcClient'EntQsPlc_ASC.DLL是Q系列以太网通讯组件
    Public Declare Function timeGetTime Lib "winmm.dll" () As UInt32

    Private Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load
        Me.CenterToScreen()
        cmbReadMry.Items.Clear()
        cmbReadMry.Items.Add("X")
        cmbReadMry.Items.Add("Y")
        cmbReadMry.Items.Add("M")
        cmbReadMry.Items.Add("D")
        cmbReadMry.Items.Add("R")
        cmbReadMry.Items.Add("Z")
        '
        cmbWriteMry.Items.Clear()
        cmbWriteMry.Items.Add("X")
        cmbWriteMry.Items.Add("Y")
        cmbWriteMry.Items.Add("M")
        cmbWriteMry.Items.Add("D")
        cmbWriteMry.Items.Add("R")
        cmbWriteMry.Items.Add("Z")
        '
        cmbBitMry.Items.Clear()
        cmbBitMry.Items.Add("X")
        cmbBitMry.Items.Add("Y")
        cmbBitMry.Items.Add("M")
        '
        cmbReadType.Items.Clear()
        cmbReadType.Items.Add("INT16")
        cmbReadType.Items.Add("UINT16")
        cmbReadType.Items.Add("DINT32")
        cmbReadType.Items.Add("HEX32")
        cmbReadType.Items.Add("REAL32")
        cmbReadType.Items.Add("BIN16")
        '
        cmbWriteType.Items.Clear()
        cmbWriteType.Items.Add("INT16")
        cmbWriteType.Items.Add("UINT16")
        cmbWriteType.Items.Add("DINT32")
        cmbWriteType.Items.Add("HEX32")
        cmbWriteType.Items.Add("REAL32")
        cmbWriteType.Items.Add("BIN16")

        cmbReadMry.SelectedIndex = 3
        cmbWriteMry.SelectedIndex = 3
        cmbBitMry.SelectedIndex = 2
        cmbReadType.SelectedIndex = 0
        cmbWriteType.SelectedIndex = 0
        lstRead.Items.Clear()
        txtWrite.Text = ""
        '
        cmbCmdType.SelectedIndex = 0
    End Sub


    Private Sub butLink_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butLink.Click
        Dim re As Short
        Dim restr As String = ""
        re = PLC.EntLink(Trim(txtLocalIP.Text), Val(txtLocalPort.Text), Trim(txtRemoteIP.Text), Val(txtRemotePort.Text), "DEMO", Handle1, 1000, CBool(cmbCmdType.SelectedIndex))
        txtReLink.Text = re.ToString
        If re = 0 Then
            EntLink1 = True
            MsgBox("PLC联接成功! ")
        Else
            EntLink1 = False
            MsgBox("PLC联接失败: " & restr)
        End If
    End Sub           


    Private Sub butClose_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butClose.Click
        Dim re As Short
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        re = PLC.DeLink(Handle1)
        txtReClose.Text = re.ToString
    End Sub



    Private Sub butRead_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butRead.Click
        Dim re As Short
        Dim i As Short
        Dim RD() As Object
        ReDim RD(Val(txtReadCnt.Text - 1))
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            ' Exit Sub
        End If
        Dim mry As EntQsPlc_Asc.PlcClient.PlcMemory = cmbReadMry.SelectedIndex + 1
        Dim typ As EntQsPlc_Asc.PlcClient.DataType = cmbReadType.SelectedIndex + 1
        re = PLC.CmdRead(Handle1, mry, typ, CInt(txtReadAdd.Text), CUShort(txtReadCnt.Text), RD)
        txtReRead.Text = re.ToString
        lstRead.Items.Clear()
        For i = 0 To UBound(RD) Step 1
            If Not IsNothing(RD(i)) Then lstRead.Items.Add(RD(i))
        Next i
        If re <> 0 Then
            Timer1.Enabled = False
            butScan.Text = "Cycle R/W"
        End If
    End Sub



    Private Sub butWrite_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butWrite.Click
        Dim re As Short
        Dim i As Short
        Dim temp() As String
        Dim WD() As Object
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        ReDim WD(Val(txtWriteCnt.Text) - 1)
        temp = Split(txtWrite.Text, vbCrLf)
        For i = 0 To UBound(WD) Step 1
            If i > UBound(temp) Then
                WD(i) = 0
            Else
                WD(i) = Trim(temp(i))
            End If
        Next i
        Dim mry As EntQsPlc_Asc.PlcClient.PlcMemory = cmbWriteMry.SelectedIndex + 1
        Dim typ As EntQsPlc_Asc.PlcClient.DataType = cmbWriteType.SelectedIndex + 1
        re = PLC.CmdWrite(Handle1, mry, typ, CInt(txtWriteAdd.Text), CUShort(txtWriteCnt.Text), WD)
        txtReWrite.Text = re.ToString
        If re <> 0 Then
            Timer1.Enabled = False
            butScan.Text = "Cycle R/W"
        End If
    End Sub
    
    
    Private Sub butScan_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butScan.Click
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        Timer1.Enabled = Not Timer1.Enabled
        If Timer1.Enabled Then
            ScanCount1 = 0
            butScan.Text = "Stop R/W"
        Else
            butScan.Text = "Cycle R/W"
        End If
    End Sub



    Private Sub Timer1_Tick(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Timer1.Tick
        Timer1.Enabled = False
        Dim tim As Integer = timeGetTime
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        '
        Call butRead_Click(Nothing, Nothing)
        Call butWrite_Click(Nothing, Nothing)
        '
        If (Val(txtReRead.Text) < 0) Or (Val(txtReWrite.Text) < 0) Then
            butScan.Text = "Cycle R/W"
            Exit Sub
        Else
            ScanCount1 += 1
            txtScanCnt.Text = ScanCount1
            txtScanPrd.Text = (timeGetTime - tim) & "ms"
        End If
        Timer1.Enabled = True
    End Sub

    Private Sub butBitTest_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butBitTest.Click
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        Dim rd As Boolean
        Dim re As Short
        Dim mry As EntQsPlc_Asc.PlcClient.PlcMemory = cmbBitMry.SelectedIndex + 1
        re = PLC.Bit_Test(Handle1, mry, CUShort(txtBitAdd.Text), rd)
        txtBitTest.Text = rd
        txtReBit.Text = re
    End Sub




    Private Sub butBitSet_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butBitSet.Click
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        Dim re As Short
        re = PLC.Bit_Set(Handle1, cmbBitMry.SelectedIndex + 1, Val(txtBitAdd.Text))
        txtReBit.Text = re
    End Sub



    Private Sub butBitRst_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butBitRst.Click
        If Not EntLink1 Then
            MsgBox("还未与PLC建立联接!")
            Exit Sub
        End If
        Dim re As Short
        re = PLC.Bit_Reset(Handle1, cmbBitMry.SelectedIndex + 1, Val(txtBitAdd.Text))
        txtReBit.Text = re
    End Sub

End Class
全部回答
相关资源可以搜一下ComFxPlc/ComQsPlc等资源;
我要举报
如以上问答信息为低俗、色情、不良、暴力、侵权、涉及违法等信息,可以点下面链接进行举报!
大家都在看
5cm厚AC-20C中粒式改性沥青的密实度是多少?
宝马x3故障码12b104废气触媒转换器前氧传感器
3ds突然出现变成这样,怎么办啊
检针机·检测灵敏度 fe代表铁feΦ0.8mmfeΦ1.
单选题从沸腾炉出来的炉气必须净化的原因是A.
怎样把菜做的很麻很麻……
电脑上出现此计算机没有并口或并口被禁用不能
喜欢一个人是爱占她便宜,还是不忍心动她。
A: children there are in a famil
斩赤红之瞳里面。至高帝具和恶魔之粹谁更强,
财务什么叫一级二级三级帐
农村商业银行(大寨乡新立村)地址有知道的么?
剑灵烛魔8段比烛魔5段输出提升大不大?
已知lx+3又1/2l与ly-2又1/2l互为相反
我和她还有她闺蜜。走在大街上她吃冰淇淋,而
推荐资讯
怎么把扩展名为pic的图片转变为jpg或gif格式
54颗佛珠怎么穿
社团中财政部招新,我得问什么问题?
如何用换手率选股?
网球肘能使手臂伸不直吗
单选题下列各句中,没有语病的一句是A.人类文
什么是外贸报关台账,怎么做?
he(宾语)
足球客场和主场是什么
月嫂初次入户怎么做首先月嫂该做什么
用滑板滑雪,急
四川考生是选天津工业大学好(在川内属于二本
正方形一边上任一点到这个正方形两条对角线的
阴历怎么看 ?