kic2000炉温测试仪从炉子里出来读不出数据怎么办?
答案:5 悬赏:10 手机版
解决时间 2021-03-26 10:51
- 提问者网友:半生酒醒
- 2021-03-26 03:58
kic2000炉温测试仪从炉子里出来读不出数据怎么办?
最佳答案
- 五星知识达人网友:迷人又混蛋
- 2021-03-26 05:30
通常是仪器过热自动保护后怎样进行复位?
退出KIC2000软件
1,找到KIC Profiler 2000\Log\kic2000usersettings.kiccfg ,用记事本方式打开
2,把文件中的ViewHostDialog=0改为=1,然后保存并退出。
再次启动KIC2000软件你就可以看到KICHost界面了。
Can try these steps, remark to using English Language
Recommend is use 9V ALKALINE Battery
1. Make sure the SlinKIC2000 software is close.
2. Under the root directory on your hard drive, under the folder the KIC Profiler 2000 you will find a folder called "Log".(Using Windows Explorer, open the X:\KIC Profiler 2000\Log\kic2000usersettings.kiccfg file)
3. Under the Log folder there is a file called "KIC2000UserSettings.KICCFG"
4. Open this file using Note or WordPad text editor.
5. With file opened under the text editor, find the line: ( " ViewHostDialog=0", Set this line to =1, Save changes to the file. )
6. Restart the SlimKIC2000 software and you motice that a second application will open, the KIC Host. ( On the Windows Taskbar, click on the "KIC Host" tab)
7. Direct connection to SlimKIC2000, restart SlimKIC2000 Unit.
8. Select "Configure SlimKIC" .
9. Another Window will open. Select "Write SlimKIC Setuop" . You should see dialog appear in that window which says " Write SlimKIC Successful".
由深圳市时汉电子为你专业服务,如有不明白的地方。CALL: 138 0270 8085 唐/R
退出KIC2000软件
1,找到KIC Profiler 2000\Log\kic2000usersettings.kiccfg ,用记事本方式打开
2,把文件中的ViewHostDialog=0改为=1,然后保存并退出。
再次启动KIC2000软件你就可以看到KICHost界面了。
Can try these steps, remark to using English Language
Recommend is use 9V ALKALINE Battery
1. Make sure the SlinKIC2000 software is close.
2. Under the root directory on your hard drive, under the folder the KIC Profiler 2000 you will find a folder called "Log".(Using Windows Explorer, open the X:\KIC Profiler 2000\Log\kic2000usersettings.kiccfg file)
3. Under the Log folder there is a file called "KIC2000UserSettings.KICCFG"
4. Open this file using Note or WordPad text editor.
5. With file opened under the text editor, find the line: ( " ViewHostDialog=0", Set this line to =1, Save changes to the file. )
6. Restart the SlimKIC2000 software and you motice that a second application will open, the KIC Host. ( On the Windows Taskbar, click on the "KIC Host" tab)
7. Direct connection to SlimKIC2000, restart SlimKIC2000 Unit.
8. Select "Configure SlimKIC" .
9. Another Window will open. Select "Write SlimKIC Setuop" . You should see dialog appear in that window which says " Write SlimKIC Successful".
由深圳市时汉电子为你专业服务,如有不明白的地方。CALL: 138 0270 8085 唐/R
全部回答
- 1楼网友:長槍戰八方
- 2021-03-26 09:11
首先KIC2000在很早以前已经停产了,如果你还能在市场上购买到像KIC 2000,KIC Start, KIC Explorer,可以很肯定的告诉你已经买到假货了,因为这些在很早以前已经停产了。你可以联系KIC原厂进行辨别仪器的真假。
建议使用KIC最新款的智慧型测温仪SPS(Smart Profiler System),并且能够数据对接MES,助你在工业4.0更一步提升。了解更多请登入KIC官网:
软件
程序平台:Profiling Software 2G 平台兼容X5 and/or K2 系列型号
功能标配:
A:组合式下载方式:数据传输、无线传输、存储+无线传输
B:SPC chart and CpK 组合计算
C:Navigator Power 自动预测/优化设置
D:曲线重合比对
E:PWI 工艺指标量化
F:安卓手机平台APP 查看曲线
等等 。。。
硬件
A:全新隔热套开启方式比X5隔热能力提升15%
B:可充电电池
C:独创Wifi + ANT 无线传输模式
D:Stacking 存储模式
E:采样频率:50per/second
F:10分钟快充技术(10 minute charge to collect 1 profile)
G:数据点:72K per/Channel
H:Profile Stacking: 30 typical profiles(Usage between charging )
I:WiFi: ~15 profiles (Usage between charging )
J:快速冷却的组合材料
K:自动休眠技术
L:自动ANT 无线对接
M:下载组合方式:数据下载、无线Wifi下载、存储模式+WiFi下载
- 2楼网友:忘川信使
- 2021-03-26 08:17
隔热盒垃圾!芯片受到高温了。
- 3楼网友:拜訪者
- 2021-03-26 07:09
1,没电了 2,通讯线有问题 3,开机与记录有误,没采集到数据 4,仪器主板坏了。追问:
kic2000炉温测试仪在完成曲线测量后,数据不能下载到电脑上,且曲线往下跑,
且报什么“必须超过启动点130以上。。。。”什么的
用其他PCBA测量可以,请教大家是怎么回事啊
kic2000炉温测试仪在完成曲线测量后,数据不能下载到电脑上,且曲线往下跑,
且报什么“必须超过启动点130以上。。。。”什么的
用其他PCBA测量可以,请教大家是怎么回事啊
- 4楼网友:街头电车
- 2021-03-26 06:56
曲线往下跑是测温线正负极接反了
报“必须超过启动点130以上。”你的温度太低。仪器认为你没有完成一次炉温测试,所以不能下载。如有需要可以电话186 203 77855,换几条新的测温线就行了
报“必须超过启动点130以上。”你的温度太低。仪器认为你没有完成一次炉温测试,所以不能下载。如有需要可以电话186 203 77855,换几条新的测温线就行了