ul1017与1015的差别是什么
答案:2 悬赏:0 手机版
解决时间 2021-02-09 05:23
- 提问者网友:藍了天白赴美
- 2021-02-08 04:30
ul1017与1015的差别是什么
最佳答案
- 五星知识达人网友:掌灯师
- 2021-02-08 04:36
1007,PVC Insulated Wire. 80C, 300 V.
Conductor :32-16 AWG, solid or stranded.
Insulation:PVC, 15 mils minimum average, 13 mils minimum at any point, 60 or 80C in oil, if applicable.
_______________________________________________________________
1015,PVC Insulated Wire. 80C, 90C or 105C; 600 V ac, 750 V dc.
Conductor :30 AWG - 2000 kcmil.
Insulation:PVC,Min. Avg. 30mils,Min at Any Point 27 mils。
Conductor :32-16 AWG, solid or stranded.
Insulation:PVC, 15 mils minimum average, 13 mils minimum at any point, 60 or 80C in oil, if applicable.
_______________________________________________________________
1015,PVC Insulated Wire. 80C, 90C or 105C; 600 V ac, 750 V dc.
Conductor :30 AWG - 2000 kcmil.
Insulation:PVC,Min. Avg. 30mils,Min at Any Point 27 mils。
全部回答
- 1楼网友:深街酒徒
- 2021-02-08 05:47
这两个型号同为758电子线,相同awg时,导体规格上并没有哪个有规定材料结构上的差别,绝缘材料也同为pvc.
如果需要要软的,建议采购时要求导体的结构,要求厂家使用更细的导体,更多的条数,但这样价格会上升.